The hopper calibration device adopts full-scale calibration, and the system accuracy can reach 0.1%. It takes an average of 2-3 hours to complete the rapid calibration of the hopper (including adjustments). There is no need to purchase/rent and carry weights, no substitutes such as purified water, and no need to open. Material tanks, eliminating the risk of contamination; simulating the actual loading of materials tanks, errors caused by hardware such as pipelines and foundations can be compensated, and a complete traceable data source is provided.
020-34563445The hopper scale on-site weightless calibration device consists of a pressure gauge, a screw jack and a special loading mechanism. According to the principle of superimposed force measuring machine, it is a set of devices (equipment) to determine whether the scale is in normal state by comparing the output data of the pressure meter and the load cell on the scale. It is suitable for calibration of weighing equipment made of application modules and for large tonnages where small table weights cannot be placed and for hopper scales.
Rapid Calibration for Reactor Weighing is an innovative calibration method for tanks, reactors, hoppers and silo scales. It ensures that accurate calibration results are achieved while at the same time meeting the traceability requirements of various quality control systems. Traditional calibration methods are time-consuming, expensive and often uncertain in terms of accuracy and traceability of calibration results. The innovative Weigh Tank Rapid Calibration is a traceable and economical method of calibrating tank scales without the use of test weights or purified water. It also eliminates the risk of contamination inside the tank by eliminating the costly and risky process of material substitution.
Performance indicators and functions
1、Range:1~100t optional
2、Accuracy level: 0.1% F.S.
3、Measuring channel: 1~4 way optional
4、System pressure stabilization time: more than 30S
5、Display meter: LCD display each way weight and total weight.
6、Screw jack, pressure stabilization, small size, easy to carry.
7、instrumentation and power supply system portable design, AC and DC dual-use, easy to carry.




                                        

                                        
                                        
                                        
                                        
                                        
                                        
                                        
                                        



                                                    





                                        
                                        
                                        